{"product_id":"replacement-calibration-object-roland-dwx-51d","title":"Replacement Calibration Object for Roland® DWX-51D","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eKeep Your DWX-51D Milling with Confidence\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe calibration object is an essential component used to calibrate the Roland® DWX-51D milling machine. If it becomes damaged or lost, the machine cannot be properly calibrated, resulting in unnecessary downtime and interrupted production.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDenteon manufactures a precision aftermarket replacement calibration object specifically for the DWX-51D, helping laboratories keep these proven legacy milling machines operating long after OEM support has ended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eManufactured in-house using precision machining processes, every calibration object is built to provide the fit, function, and reliability expected in a production dental laboratory.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e✔ Precision manufactured by Denteon\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✔ Designed specifically for the Roland® DWX-51D\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✔ Complete assembled calibration object\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✔ Ready for immediate use\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e\u003cbr\u003eEngineered for Legacy DWX-51D Machines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor more than a decade, the Roland® DWX-51D has earned a reputation as one of the most reliable dental milling machines ever produced. Many of these mills remain in daily production, manufacturing restorations for laboratories around the world.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAs these machines continue to provide dependable service, replacement components have become increasingly difficult to obtain.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTo help laboratories protect their investment, Denteon manufactures this precision aftermarket calibration object specifically for the DWX-51D. Every calibration object is produced in-house and inspected to help ensure the accuracy and consistency required for machine calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOur focus has always been helping customers maximize the life of their equipment. This calibration object is one example of that commitment—providing laboratories with a dependable solution that helps keep proven DWX-51D mills operating productively.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e\u003cbr\u003eBuilt for Reliable Performance\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003ePrecision Manufactured\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEach calibration object is precision machined in Denteon's California manufacturing facility using industrial CNC equipment, then inspected prior to shipment to help ensure accurate fit and reliable performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eComplete Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSupplied as a complete, fully assembled calibration object, ready for immediate use with the Roland® DWX-51D.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDesigned Specifically for the DWX-51D\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEngineered exclusively for the Roland® DWX-51D to provide compatibility with the machine's standard calibration procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eProtect Your Productivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA damaged or missing calibration object can bring calibration procedures to a halt. Keeping a replacement available helps minimize unexpected downtime and allows your laboratory to return to production quickly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eManufactured in the USA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDesigned, precision machined, assembled, and inspected by Denteon in California, USA.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eWhy Keep a Spare?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe calibration object is one of the few components on the DWX-51D that can be accidentally damaged during normal operation. If it is left installed in the machine when a machining job is started, it can be struck by the spindle and rendered unusable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWithout a functional calibration object, the machine cannot be properly calibrated. Having a spare on hand allows calibration to be completed immediately, helping to avoid unnecessary downtime and keeping production on schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor many laboratories, a spare calibration object is inexpensive insurance against an unexpected interruption in production.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e\u003cbr\u003eCompatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCompatible With\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-51D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eNot Compatible With\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-52 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-52D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-52DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-52DCi\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-53D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-53DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRoland® DWX-42W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDGSHAPE DWX Series not listed above\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis calibration object has been designed exclusively for the DWX-51D platform and should not be used with other Roland® or DGSHAPE milling machines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIs this an OEM Roland® calibration object?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo. This product is manufactured by Denteon and is an aftermarket replacement designed specifically for the Roland® DWX-51D. It is not an OEM Roland® product.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat OEM parts does this replace?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis calibration object is a complete assembled replacement for the Roland® DWX-51D calibration object.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIt cross-references the following Roland® service parts:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBase, Correction Jig DWX-51D\u003c\/span\u003e\u003cspan\u003e — Part No. \u003c\/span\u003e\u003cspan\u003e1000013686\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eShaft, Correction Jig DWX-51D\u003c\/span\u003e\u003cspan\u003e — Part No. \u003c\/span\u003e\u003cspan\u003e1000013687\u003c\/span\u003e\u003cspan\u003e (Qty. 3)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis product includes the complete assembled calibration object.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWill this work with my DWX-51D?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes. This calibration object is designed specifically for the Roland® DWX-51D and is compatible with the machine's standard calibration procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhy would I need a replacement calibration object?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe most common cause of damage is accidentally leaving the calibration object installed in the machine when a machining job is started. If struck by the spindle, the calibration object can become unusable and should be replaced before further calibration procedures are performed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eShould I keep a spare?\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWe recommend that every DWX-51D owner keep a spare calibration object available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHaving a spare on hand can help minimize unexpected downtime, allowing calibration to be completed immediately if the original calibration object is damaged or lost.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhere is this product manufactured?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEvery calibration object is designed, precision machined, assembled, and inspected by Denteon in California, USA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1 dir=\"ltr\"\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"184\"\u003e \u003ccol width=\"272\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCalibration Object Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMachine Compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRoland® DWX-51D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAftermarket Replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAssembly Included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes – Complete Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eManufactured By\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDenteon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInspection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIndividually inspected prior to shipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eLegal Notice\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRoland® and DWX® are registered trademarks of their respective owners. This product is manufactured by Denteon and is not an OEM Roland® product. Roland® product names and part numbers are used solely to identify compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Denteon","offers":[{"title":"Default Title","offer_id":48939208310967,"sku":null,"price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9037\/5351\/files\/MAINIMAGE51D_Calibration_Object_OEM_1.png?v=1785377928","url":"https:\/\/denteon.com\/products\/replacement-calibration-object-roland-dwx-51d","provider":"Denteon","version":"1.0","type":"link"}